Part #
The Drain Manifold Assembly is used in the XT15/XT15I Fat Extractors. It receives water from multiple cooling coils and routes it to the waste line.
Part #
Used within the Extraction Vessel of the XT10/XT10I and XT15/XT15I, this assembly includes a Cup Insert and a Wave Spring Bag Holder.
Part #
This is the internal computer that controls the XT10 Fat Extractor.
Part #
This kit includes replacement pistons for the two solvent valves (Q5 and Q6).
Part #
The TDF107 Synthetic Grease, 10 gm, is a non-toxic lubricant used to minimize friction within the peristaltic pump, thereby extending the life of peristaltic pump tubing. For application instructions, see TDF Service Procedure Long Life Pump Tube...
Part #
This is the programmed touchscreen hardware used in the human interface module. This part can be purchased to replace an existing touchscreen that may be damaged in some way.
Part #
This circuit board contains the electronics that control the instrument.
Part #
The Mixer Flow Control Valve Assembly allows for better control and easier adjustment to the intensity of sample mixing to help ensure proper digestion.
Part #
The Internal Drain Hose Assembly with check valves delivers necessary chemicals for each assay. Included in the assembly are tubes that drain chemicals after their use.
Part #
Located in #FLEX30 Slide Valve and #FLEX32 Vent Valve assemblies Rev A.
Part #
Replacement Vent Bottle & Tube Assembly for XT15/XT15I. This includes SS tube with compression fitting, bottle cap, 500ml coated glass bottle, and 6 ft. of chemical resistant tubing.
Part #
This kit and the accompanying process guide provide the parts and the instructions to complete the Preventative Maintenance (PM) process for the DELTA or A2000 Automated Fiber Analyzers. This procedure should be completed annually for an instrument...
Part #
This Extraction Vessel seal should be used when running Pet Ether in your XT10/XT10I and XT15/XT15I.
Part #
The Thermal Cut-off Assembly is used in the heater for the oven. It consists of a non-resettable thermal fuse that shuts down power to the heater if the temperature exceeds 240°C.
Part #
The Vent Valve Assembly functions to release pressure from the vessels during vessel fill and saponification.
Part #
This part displays the solvent level on the XT15/XT15I instruments.
Part #
This container can be used for storing solvents when not in use. When the instrument is properly configured, a cubitainer can also be used for automatically dispensing solvents during an assay. The CUBITAINER® is a disposable flexible package. It can...
Part #
Replacement quick-release connector insert used on the ends of the supply tubes, which connect into the top of the alcohol, buffer, and water containers. Please specify the color: Blue , Red , Green , or White .
Part #
This is a replacement upper tray for the bag suspender which is found in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. Eight of these are used in the bag suspender assembly.
Part #
This is a maintenance tool used to clean the (6) 0.020" (0.5mm) holes in the spray tip.
Part #
The Valve Piston w/Viton® Seat is used inside the solenoid supply valves on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments and to replace a damaged, worn, or corroded component. DELTA: found in the Vent...
Part #
The Chemical Receptacle is used to house an NaOH (or stronger Base) when performing oxygen consumption studies. The function of the Base material is to scavenge the CO2 produced by the aerobic metabolism. This produces a negative pressure as the O2...
Part #
The RFI Filter 120v/220v is a power receptacle used on the DELTA/DELTAI, A200I, and A2000/A2000I. It is not used on the A200. It is located on the side of the instrument and connects the instrument to a power source through a removable power cord.
Part #
Useful in the AOAC 2009.01/2011.25 methods, this cup is used to capture the filtrate that comes through the SDF Filter Bag.
Part #
These lamps light the inside of the heat and agitate switches.
Part #
This quick disconnect fitting mounts onto either side of the upper enclosure of the A2000/A2000I Fiber Analyzers. The part is used to connect to the detergent solution cubitainers.
Part #
The replacement Hose Coupler is used on the DELTA/DELTAI, A200/A200I, and A2000/A2000I Fiber instruments. It connects to the drain hose at the side of the instrument. Includes 2 pieces.
Part #
Two versions of software are available depending on the RFS#: RF3: RF GPM Software 11.4 RF3X: RF GPM Software 15.0 This update to the GPM software is a major enhancement that includes many new features including: Enables up to 10 systems in one...
Part #
The TDF120 In-Line heater Core is used to replace leaking brass tubing on the In-Line Heater. It includes connected silicone tubing for ease of installation. The heater cartridge and thermistor (temp sensor) are not included in this assembly.
Part #
The HCl Extraction Chamber must be sealed during an assay. The H2 Lid/Latch Assembly seals the Extraction Chamber in the HCl instrument. This assembly includes the latch that secures the lid to the instrument.
Part #
The HCl Extraction Chamber must be sealed during an assay. The H3 lid seals the Extraction Chamber in the HCl instrument. This assembly does not include the latch that secures the lid to the instrument.
Part #
The H37 Bag Holder is used to hold the bags in the HCl/HClI Extraction Chamber during as assay. This assembly holds 15 bags. Can also be used in the RD/RDI Dryers.
Part #
This bolt is used for securing the lid and hinge block assembly to the vessel.
Part #
Attaches on the top of the RD/RDI Dryer. This filter is used when drying filter bags before and after a fat extraction done with an ANKOM XT10/XT10I or an ANKOM XT15/XT15I Extractor.
Part #
The RF Gas Production System bottles that include a septa port use a 3 mm 2-sided PTFE coated Silicone Septa to provide an easy to penetrate seal while providing minimal pressure loss per penetration. The RF35 pack includes 10 septa.
Part #
The Process Pump is the fluid delivery pump used to deliver all reagents from the reservoirs to the vessels.
Part #
The Motor with 4-wire cable is a stepper motor which operates the vessels' magnetic stirrers.
Part #
The FLEX24 High Temperature Thermistor Assembly is marked 56 and is used to monitor the temperature within the oven.
Part #
The TDF129 kit provides all the tubing and parts necessary to perform the annual maintenance for a TDF instrument. This includes all the supply tubing, delivery tubing, enzyme tubing, and all related tubing plus several parts that can fatigue over...
Part #
The Amylase Dispenser connects to the DELTA/DELTAI instrument and is used as a reservoir to dispense amylase into the vessel for digestion of starch during a Neutral Detergent fiber analysis.
Part #
This drive roller connects the motor to the drive pulleys.
Part #
This is a 100 hr timer assembly for monitoring incubation times of samples in the ANKOM Daisy II Incubator (D200/D200I).
Part #
The Kynar Tip and Washer assembly is used when the Kynar tip has become worn. It is located at the bottom of the bag suspender used in the DELTA/DELTAI, A200/A200I, and A2000/A2000I Fiber instruments. A worn tip can inhibit proper agitation and...
Part #
This part protects the 120v A200 instrument against power surges that are out-of-specification.
Part #
To protect the interior of the instrument, this collection chamber catches fluid in the event of an internal leak.
Part #
This assembly shows if the packing has started to leak.
Part #
The RF41 Synthetic Grease w/PTFE is a non-toxic lubricant used to assist in creating a seal between the RF34 Viton® Gasket and the module/bottle, and between the PTFE coated septa and the septa port on the bottle. For application instructions...