Part #
This part protects the 220v instrument against power surges that are out-of-specification.
Part #
The Open End Wrench 1-1/8" is used to tighten the Brass Packing Nut ( Part #: 640 ) found on the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments.
Part #
This is the controller with display used in the 220v RD Dryer.
Part #
The Pressure Sensor Assembly is used in the DELTA & DELTAI Fiber instruments for measuring the initial pressure before a run. It also measures the pressure during a run to monitor the process and ensure proper extraction.
Part #
The Splat Controller w/ Spice Board is used in the DELTA Fiber instrument and holds the program, controlling all funtions of the DELTA instrument.
Part #
This is the Low Pressure Regulator for the TDF instrument.
Part #
Individual replacement paddle for the ANKOM TDF paddle bar. Includes embedded temperature sensor and heater cartridge.
Part #
The Temperature Probe w/ ground terminal is used in the DELTA/DELTAI and A2000/A2000I Fiber instruments. This probe provides an accurate vessel temperature which is displayed on the Ascon controller.
Part #
The Lid Assembly is used on the DELTA/DELTAI and A2000/A2000I Fiber instruments and seals the top of the digestion vessel.
Part #
This assembly heats the digestion vessel in the 220v A200I instrument.
Part #
The Outer Exhaust Hose Assembly is used in the DELTA/DELTAI and A200/A200I Fiber instruments. It drains waste solutions from the digestion vessel.
Part #
The Bag Suspender Rod w/ Nut Assembly is used when damage to the rod or pitting has occurred. It runs through the middle of the bag suspender and holds the nine trays in place and is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber...
Part #
The Bag Weigh Holder is used to hold a filter bag open for easy insertion of the sample. This part is especially useful during the weighing process.
Part #
The Hinge Block Assembly is found in the A200/A200I Fiber Instruments. The assembly includes a shoulder bolt and is used to secured the lid to the vessel during sample digestion.
Part #
This hose carries waste from the vessel to the outer exhaust hose. Includes hose with clips.
Part #
This assembly heats the digestion vessel in the 120v instrument.
Part #
This larger 4 liter chemical container is used for supplying distilled water to the instrument. The larger size accommodates 8 runs on the instrument before refilling is necessary.
Part #
This holder is used to position the Distilled Water, Buffer, and 78% EtOH containers in the appropriate location next to the instrument.
Part #
This 10 amp fuse is used on the DELTAI and A2000I Fiber instruments (220v) along with RD (120v) and RDI (220v). It helps protect the instrument from a possible power surge.
Part #
The ANKOM RF Maintenance Kit provides the essential tools needed to keep your RF Gas Production System operating smoothly. The following items and instructions for each are included: - (1) RF70: Positive Control Capsule Set (set includes 5 BLUE...
Part #
The Pump assembly is found in the DELTA/DELTAI Fiber instruments and includes a fill valve and pump to supply the vessel with chemicals and rinse water.
Part #
This is the High Pressure Regulator for the TDF instrument.
Part #
For use in the ANKOM FLEX Analyte Extractor. Precision ground glass vessel with port and cap; used in the digestion step of the analysis. The port allows the addition of internal standards. A FLEX55 combined with a FLEX54 form a complete Digestion...
Part #
For use in the ANKOM FLEX Analyte Extractor. High Strength PTFE magnetic stir-bar; used in each assembled digestion vessel for more difficult to mix samples.
Part #
For use in the ANKOM FLEX Analyte Extractor. Precision ground round bottom flask with a 34-15 taper ground joint; used in the evaporation step of the instrument.
Part #
Power Supply A is a 10 amp transformer that supplies 24v DC power to the pump motor controller (PMC) and analog multiplexer boards MUX-T ( Part #: TDF111 ) and MUX-P ( Part #: TDF112 ). This supply is used for both 110v and 220v instruments.
Part #
These bulbs are used for heating the 120-130v DAISY instrument.
Part #
This relay monitors the heaters in the following ANKOM instruments: XT15I, XT10I, HClI, DELTAI, and A2000I.
Part #
This is the internal computer that controls the HCl instrument.
Part #
This assembly heats the Extraction Chamber of the 220v HCl instrument.
Part #
The H4 valve is a replacement Water Supply Valve for the HCl/HClI. For replacement instructions, refer to Service Procedure Water Supply Valve Installation (H4) (HS003).
Part #
The RF Gas Production System uses rechargeable battery packs ( #RF16 / #RF46 ). The RF25 10-Station Battery Charger is used to charge the RF16/RF46 Rechargeable Battery Packs. As the name says, this charger can charge 10 batteries at one time.
Part #
The pneumatically-operated Diaphragm Valve regulates the input of HCl or Acetic Acid. Refer to Service Procedure Diaphragm Valve Replacement (TS016) for installation instructions.
Part #
The Pump Assembly includes the pump head, motor, and bracket. This pump moves fluids by peristaltic action delivering fluids to the six positions.
Part #
This relay replaces Part #: 6114 and controls power to the Ascon temperature controller, motor, and drain valve on the DELTA/DELTAI and A2000/A2000I Fiber instruments, as well as the HCl/HClI instrument.
Part #
This one-way valve is used for adding gas into the glass bottle of an RF1 module. This is often done to purge the bottle of existing gases. To push gas into the bottle using an Air Purge Assembly ( Part #: RF28 ), see RF Service Procedure Purge...
Part #
The Black Nitrogen Supply Tubing is used as a replacement part for cracked or damaged nitrogen supply tubing or where additional length is required. The unit price is per foot. Please specify the length in the quantity field when ordered.
Part #
This is the internal computer that controls the A2000 Fiber Analyzers.
Part #
The A10 Motor Assembly 220v drives the agitation system in the 220v DELTAI & A2000I.
Part #
This is an enzyme container used for supplying Protease to the instrument.
Part #
This is a chemical container used for supplying 78% EtOH to the instrument.
Part #
The Safety Cover with Handle is used to prevent incidental splashing of fluids and assists with preventing drafts during bag heating.
Part #
Replacement silicone tubing (uncut) for all 3/16" OD tubing. Refer to TDF Service Procedure Tube Replacement (Delivery) (TS006) for installation instructions.
Part #
The Bag Weight Machined is used on the top of the bag suspender within the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It is necessary to hold the trays in place, which, in turn, hold the filter bags in suspension, during the digestion...
Part #
This thermistor is used to measure the temperature within the RD/RDI Dryers drying chamber.
Part #
Waste fluids flow through the Drain Tray Tube from the instrument to a waste drain or container. The Drain Tray Tube Kit comes with 6 ft. of Drain Tube, (1) 6138 Tube Clamp, (2) 8288 Elbow Connectors, and (1) 8133 Adhesive Clamp that is used to hold...