Part #
The ANKOM RD Dryer 120v 50/60 HZ is designed to dry samples and resist corrosion. The following two filters can be used with the RD Dryer depending on your application: 1) The RD1 Dryer Activated Carbon Filter is used when drying filter bags before...
Part #
This enzyme formulation was developed specifically for use in the ANKOM TDF Dietary Fiber Analyzer. With all of the necessary ingredients in this concentrated formula, add the correct amount of water, and the enzyme solution is ready for use in the...
Part #
This enzyme formulation was developed specifically for use in the ANKOM TDF Dietary Fiber Analyzer. With all of the necessary ingredients in this concentrated formula, just add the correct amount of water and the enzyme solution is ready for use in...
Part #
These pre-inked pads are used by the TN2 numbering machine.
Part #
This enzyme formulation was developed specifically for use in the ANKOM TDF Dietary Fiber Analyzer. With all of the necessary ingredients in this concentrated formula, add the correct amount of water, and the enzyme solution is ready for use in the...
Part #
This enzyme formulation was developed specifically for use in the ANKOM TDF Dietary Fiber Analyzer. With all of the necessary ingredients in this concentrated formula, add the correct amount of water, and the enzyme solution is ready for use in the...
Part #
The TCH1 XT Chiller improves system operation and solvent recovery by maintaining optimum coolant temperature. The TCH1 chiller can be used with either the XT10 or the XT15. One Chiller can support up to two extractors at the same time. • 0° to 40°C...
Part #
At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HS Heat Sealer (120v 50/60HZ) is used for sealing ANKOM Filter Bags. The sealer dimensions are: 13.5"L x 4"W x 8"H
Part #
Replacement cover for the 120v and 220v Heat Sealers (Part #: HS , HSi ). This is applied over the heating element and held in place with clamp strips. For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
ANKOM FAA is a starch-hydrolyzing alpha-amylase enzyme with high heat and pH stability derived from a genetically modified strain of Bacillus licheniformis . FAA is used for liquification of starch during Neutral Detergent Fiber analysis.
Part #
Before doing a dietary fiber assay, you should label the filter bags in order to properly record results. Use this marker for labeling the filter bags.
Part #
This enzyme formulation was developed specifically for use in the ANKOM TDF Dietary Fiber Analyzer. With all of the necessary ingredients in this concentrated formula, add the correct amount of water, and the enzyme solution is ready for use in the...
Part #
This enzyme formulation was developed specifically for use in the ANKOM TDF Dietary Fiber Analyzer. With all of the necessary ingredients in this concentrated formula, add the correct amount of water, and the enzyme solution is ready for use in the...
Part #
To properly record results, it is best to label ANKOM Filter Bags before running an assay. The F08 Marker is an acetone resistant black marker that can be used to label ANKOM F57, F58, XT4, and In Situ Bags.
Part #
The Rapid Integrated Total Dietary Fiber Assay Kit method is validated under collaborative study (AOAC Method 2017.16, ICC Standard No. 185) and suitable for the measurement and analysis of Total Dietary Fiber as per Codex Alimentarius definition...
Part #
For the AOAC 2017.16/2009.01/2011.25 methods, this enzyme is mixed with AMG when used in the ANKOM TDF Dietary Fiber Analyzer. Contents: 12 g; ca. 75,000 U/g . From porcine pancreas. Partially purified. Free flowing powder. Directions for use in TDF...
Part #
Replacement Insulator Strip on the 120v and 220v Heat Sealers (Part #:: HS , HSi ). This is adhesive-backed and positioned beneath the heating element. For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
Replacement Silicone Rubber Gasket for upper pressure bar (in handle) of the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
This special tray system desiccator is used for high fat samples requiring weigh tins.
Part #
The TCH2 XT Chiller improves system operation and solvent recovery by maintaining optimum coolant temperature. The TCH2 chiller can be used with either the XT10 or XT15 extractors. One Chiller can support up to two extractors at the same time. • 0°...
Part #
This stamp works well for marking the F57 and F58 Filter Bags. The ink resists the chemicals and the stamp advances the number each time it is pressed down.
Part #
At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HSi Heat Sealer (220v 50/60HZ) is used for sealing ANKOM Filter Bags. Please specify the country where the heat sealer will be used so that...
Part #
Replacement Heating element for the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
This 230v Shaker Water Bath can be used to control the temperature and mixing during an assay. Spring fixtures that hold bottles in place (WB-Tray) are sold separately. Specifications for this product can be found in the attached Information Sheet.
Part #
This transformer is used to step up or down the voltage needed for a device. Since ANKOM provides a 120v Water Heater, this transformer is needed if you have a 220v power source.
Part #
This 115v Shaker Water Bath can be used to control the temperature and mixing during an assay. Spring fixtures that hold bottles in place (WB-Tray) are sold separately. Specifications for this product can be found in the attached Information Sheet.
Part #
Replacement heating element for the Water Heater, 120v ( Part #: A02 ).
Part #
Replacement heating element for the A30 Water Heater, 220v (now disconnected).
Part #
This water heater, 120v can be used with the DELTA/DELTAI and A2000/A2000I Fiber instruments. It provides the required hot rinse water for DELTA/A2000 operation. If you have a 220v connection, you will need to connect this water heater to a Voltage...