Skip to main content

Resource Center

Displaying 101 - 150 of 382
 
 

Part #

RF28

The RF28 Air Purge Assembly can be used to purge the glass bottle prior to an experiment, or to pressurize the module assembly (through the Luer Duckbill Check Valve, Part #: 7139 ) to check for leaks. For module purge instructions, see RF Service...

Price: $109.00
Quantity:
 

Part #

TDF28

The In-Line Heater Assembly is a regulated heat exchanger that pre-heats certain fluids during delivery. Refer to Service Procedure In-Line Heater Replacement (TS018) for installation instructions.

Price: $790.00
Quantity:
 

Part #

640

The Brass Packing Nut is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber Instruments. When properly tightened, this ensures that the packing materials create a seal and prevent leaks from the vessel into the interior cabinet. For the A200...

Price: $23.00
Quantity:
 

Part #

RF44

This cable is used to connect the Dual Lead Battery Pack ( Part #: RF46 ) to the 10-Station Battery Charger ( Part #: RF25 ). Longer extension cables are available upon request.

Price: $39.00
Quantity:
 
 
 
 

Part #

X96

This probe is used to measure the temperature within the Extraction Vessel of an XT10/XT10I and an XT15/XT15I.

Price: $114.00
Quantity:
 

Part #

692

The Drip Tray is part of the Maintenance Alert Assembly and is used in the DELTA, A200, and A2000 instruments. It functions as a collector for a fluid leak around the agitator, diverting it away from the motor.

Price: $7.00
Quantity:
 

Part #

693

This is a replacement bottom tray for the bag suspender, which is found in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments.

Price: $26.00
Quantity:
 

Part #

8193

Replacement quick-release connector used in the top of the alcohol, buffer, and water containers, as well as in the enzyme bracket.

Price: $33.00
Quantity:
 
 
 
 
 

Part #

H38

The H38 Internal Hose Replacement Kit includes all internal hoses for the HCl/HClI ANKOM Hydrolysis instruments as well as hose clamps and one 1/2" Barbed Tee fitting.

Price: $157.00
Quantity:
 

Part #

FLEX46

The Nitrogen Flowmeter is used to regulate nitrogen flow to FLEX instrument.

Price: $237.00
Quantity:
 

Part #

X33

This kit and the accompanying process guide provide the parts and instructions to complete the Preventative Maintenance (PM) process for the high penetration ANKOM XT15/XT15I Fat Extractor. This should be completed annually for an instrument used...

Price: $1,148.00
Quantity:
 

Part #

X30

This kit and the accompanying process guide provide the parts and instructions to complete the Preventative Maintenance (PM) process for the standard ANKOM XT10 Fat Extractor. This should be completed annually for an instrument used daily or once...

Price: $282.00
Quantity:
 

Part #

FLEX76

This access panel is designed with a viewing window, allowing users to easily monitor their slide valve condition.

Price: $58.00
Quantity:
 

Part #

1918

Replacement Insulator Strip on the 120v and 220v Heat Sealers (Part #:: HS , HSi ). This is adhesive-backed and positioned beneath the heating element. For an installation diagram, refer to the Heat Sealer Operation Manual.

Price: $14.00
Quantity:
 

Part #

1919

Replacement Silicone Rubber Gasket for upper pressure bar (in handle) of the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.

Price: $30.00
Quantity:
 
 

Part #

5653

The On/Off/Heat/Rotate Power Switch is used on the following ANKOM instruments: XT10/XT10I, XT15/XT15I, HCl/HClI, RD/RDI, TDF/TDFI, D200/D200I, DELTA/DELTAI, A200/A200I, A2000/A2000I, FLEX/FLEXI. On the D200/D200I Daisy Incubator, this switch also...

Price: $35.00
Quantity:
 

Part #

8192

This holder is used to position the HCl container in the appropriate location next to the instrument.

Price: $27.00
Quantity:
 

Part #

8306

This part protects the 220v instrument against power surges that are out-of-specification.

Price: $3.00
Quantity:
 
 

Part #

Z557

The Open End Wrench 1-1/8" is used to tighten the Brass Packing Nut ( Part #: 640 ) found on the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments.

Price: $18.00
Quantity:
 
 

Part #

DELTA17

The Pressure Sensor Assembly is used in the DELTA & DELTAI Fiber instruments for measuring the initial pressure before a run. It also measures the pressure during a run to monitor the process and ensure proper extraction.

Price: $142.00
Quantity:
 

Part #

DELTA19

The Splat Controller w/ Spice Board is used in the DELTA Fiber instrument and holds the program, controlling all funtions of the DELTA instrument.

Price: $450.00
Quantity:
 
 

Part #

TDF48

Individual replacement paddle for the ANKOM TDF paddle bar. Includes embedded temperature sensor and heater cartridge.

Price: $240.00
Quantity:
 

Part #

5806

This cup insert top seal should be used regardless of the solvent being run in the XT10/XT10I and XT15/XT15I instruments.

Price: $6.00
Quantity:
 

Part #

6058

The Vessel O-Ring is used in DELTA/DELTAI and A2000/A2000I vessel lids to seal the vessel during digestion.

Price: $17.00
Quantity:
 

Part #

6068

The Timing Belt drives the agitator in the DELTA/DELTAI and A2000/A2000I Fiber instruments.

Price: $12.00
Quantity:
 

Part #

7056

ANKOM provides many different bottles that can be connected to an RF1 Gas Production Module within the RF Gas Production System. The 7056 bottle provides the following features: - up to 250ml of space to hold analysis material - a protective coating...

Price: $51.00
Quantity:
 

Part #

7129

ANKOM provides many different bottles that can be connected to an RF1 Gas Production Module within the RF Gas Production System. The 7129 bottle provides the following features: - up to 1000ml of space to hold analysis material - an Amber tint to...

Price: $99.00
Quantity:
 

Part #

8203

This filter prevents solid material from entering the instrument through the fluid container.

Price: $11.00
Quantity:
 

Part #

A01

This shelving assembly provides a turn-key system for holding chemical cubitainers at the correct heights for use with the A2000 Automated Fiber Analyzer. For installation instructions, refer to Service Procedure Cubitainer Shelf Installation (AS024)...

Price: $630.00
Quantity:
 
 
 

Part #

TDF29.1

The pneumatically operated Pinch Valve-Waste regulates the flow of fluids to the Waste tube during line charges, flushing, and diagnostic operations. Refer to Service Procedure Pinch Valve Replacement (Output) (TS008) for installation instructions.

Price: $397.00
Quantity:
 

Part #

TDF38

This is a chemical container used for supplying HCl to the instrument.

Price: $45.00
Quantity:
 

Part #

TDF63

The Mixer Piston Assembly is a pneumatic mixer which operates the paddle bar, ensuring good sample agitation during digestion.

Price: $143.00
Quantity:
 

Part #

TDF68

This kit includes six replacement tubes for the peristaltic pump. Refer to TDF Service Procedure Tube Replacement (Silicone Pump Tubes) (TS003) for installation instructions.

Price: $125.00
Quantity:
 

Part #

TDF70

The Flush Tubing Assembly used primarily for maintenance flushing of the fluid lines which allows the user to bypass fluid containers and connect to a single supply container.

Price: $253.00
Quantity:
 

Part #

638.7

The Agitator Apron is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It serves to funnel fluid away from the motor and into the maintenance alert assembly.

Price: $16.00
Quantity: