Part #
The ANKOM RD Dryer 120v 50/60 HZ is designed to dry samples and resist corrosion. The following two filters can be used with the RD Dryer depending on your application: 1) The RD1 Dryer Activated Carbon Filter is used when drying filter bags before...
Part #
Wireless Gas Production Measurement The ANKOM RF Gas Production System provides an easy-to-use method for monitoring and measuring gas production. Samples and microbes (or other fermentation sources) are placed in the bottles; the RF sensor module is...
Part #
Automated Saponification to Isolation The ANKOM FLEX Analyte Extractor's innovative design and automated technology supports multiple analysis configurations and preparation: Vitamin & Cholesterol methods based on: AOAC 2011.07, EN-12823-1, EN-12822...
Part #
Semi-Automated Crude & Detergent Fiber Performs AOCS Ba 6a-05 Crude Fiber, Acid Detergent Fiber, and Neutral Detergent Fiber analyses for all feeds and forages. The ANKOM 200 Fiber Analyzer has been subjected to rigorous testing over a broad range of...
The ANKOM XT10 and XT10I Fat Extractors have been discontinued. The replacement products are the XT15 and XT15I . ANKOM will continue to supply service and parts for the XT10 and XT10I Fat Extractors.
Part #
Automated Crude & Detergent Fiber Analysis The ANKOM DELTA Fiber Analyzer automates fiber determinations at the highest level. Capable of Acid Detergent, Neutral Detergent, and Crude Fiber analysis (AOCS Ba 6a-05), the ANKOM DELTA includes an...
Part #
This enzyme formulation was developed specifically for use in the ANKOM TDF Dietary Fiber Analyzer. With all of the necessary ingredients in this concentrated formula, add the correct amount of water, and the enzyme solution is ready for use in the...
Part #
This enzyme formulation was developed specifically for use in the ANKOM TDF Dietary Fiber Analyzer. With all of the necessary ingredients in this concentrated formula, just add the correct amount of water and the enzyme solution is ready for use in...
Part #
RF1X Gas Production Modules can be added to an ANKOM RF Gas Production System (Base Kit). A total of 50 modules can be connected to a GEN 3 RFS system. Please specify a bottle type. NOTE: Standard RF1X modules come with 250ml bottles. For different...
Part #
This enzyme formulation was developed specifically for use in the ANKOM TDF Dietary Fiber Analyzer. With all of the necessary ingredients in this concentrated formula, add the correct amount of water, and the enzyme solution is ready for use in the...
Part #
This enzyme formulation was developed specifically for use in the ANKOM TDF Dietary Fiber Analyzer. With all of the necessary ingredients in this concentrated formula, add the correct amount of water, and the enzyme solution is ready for use in the...
Part #
Automated Crude Fat Extraction Official Crude Fat Extraction Method AOCS Am 5-04 The ANKOM XT15 Extractor provides a solution for efficient and economical solvent extraction in fat/oil analysis. Fat ranges from 0% to 100% have been accurately...
The ANKOM 2000 and 2000I Fiber Analyzers have been discontinued. The replacement products are the DELTA and DELTAI . ANKOM will continue to supply service and parts for the 2000 and 2000I Fiber Analyzers.
Part #
Automated Total Fat Extraction The ANKOM HCl Hydrolysis System provides an easy method for performing the hydrolysis step in total fat/oil analysis . Filter Bag Technology prevents sample transfer errors and allows for batch hydrolysis of up to 15...
Part #
Automated Dietary Fiber Analysis Automates AOAC 985.29, 991.43, and 2001.03 (AACC 32.07.01), and NMKL 129, 2003, AOAC 2009.01, 2011.25, 2017.16 and 2022.01 The ANKOM TDF Dietary Fiber Analyzer creates a new standard used for nutritional labeling...
Part #
Reliable In-Vitro Incubation The DAISY II Incubator has a demonstrated history of rigorous testing over a broad range of sample types. Labs around the world have achieved results in In Vitro True Digestibility, Apparent Digestibility, Rate studies...
Part #
ANKOM FAA is a starch-hydrolyzing alpha-amylase enzyme with high heat and pH stability derived from a genetically modified strain of Bacillus licheniformis . FAA is used for liquification of starch during Neutral Detergent Fiber analysis.
Part #
The Rapid Integrated Total Dietary Fiber Assay Kit method is validated under collaborative study (AOAC Method 2017.16, ICC Standard No. 185) and suitable for the measurement and analysis of Total Dietary Fiber as per Codex Alimentarius definition...
Part #
For the AOAC 2017.16/2009.01/2011.25 methods, this enzyme is mixed with AMG when used in the ANKOM TDF Dietary Fiber Analyzer. Contents: 12 g; ca. 75,000 U/g . From porcine pancreas. Partially purified. Free flowing powder. Directions for use in TDF...
Part #
This enzyme formulation was developed specifically for use in the ANKOM TDF Dietary Fiber Analyzer. With all of the necessary ingredients in this concentrated formula, add the correct amount of water, and the enzyme solution is ready for use in the...
Part #
This enzyme formulation was developed specifically for use in the ANKOM TDF Dietary Fiber Analyzer. With all of the necessary ingredients in this concentrated formula, add the correct amount of water, and the enzyme solution is ready for use in the...
Part #
This larger 4 liter chemical container is used for supplying distilled water to the instrument. The larger size accommodates 8 runs on the instrument before refilling is necessary.
Part #
This holder is used to position the Distilled Water, Buffer, and 78% EtOH containers in the appropriate location next to the instrument.
Part #
This 10 amp fuse is used on the DELTAI and A2000I Fiber instruments (220v) along with RD (120v) and RDI (220v). It helps protect the instrument from a possible power surge.
Part #
The ANKOM RF Maintenance Kit provides the essential tools needed to keep your RF Gas Production System operating smoothly. The following items and instructions for each are included: - (1) RF70: Positive Control Capsule Set (set includes 5 BLUE...
Part #
The Pump assembly is found in the DELTA/DELTAI Fiber instruments and includes a fill valve and pump to supply the vessel with chemicals and rinse water.
Part #
This is the High Pressure Regulator for the TDF instrument.
Part #
For use in the ANKOM FLEX Analyte Extractor. Precision ground glass vessel with port and cap; used in the digestion step of the analysis. The port allows the addition of internal standards. A FLEX55 combined with a FLEX54 form a complete Digestion...
Part #
For use in the ANKOM FLEX Analyte Extractor. PTFE magnetic cross stir-bar; used in each assembled digestion vessel.
Part #
For use in the ANKOM FLEX Analyte Extractor. Precision ground round bottom flask with a 34-15 taper ground joint; used in the evaporation step of the instrument.
Part #
Power Supply A is a 10 amp transformer that supplies 24v DC power to the pump motor controller (PMC) and analog multiplexer boards MUX-T ( Part #: TDF111 ) and MUX-P ( Part #: TDF112 ). This supply is used for both 110v and 220v instruments.
Part #
These bulbs are used for heating the 120-130v DAISY instrument.
Part #
This relay monitors the heaters in the following ANKOM instruments: XT15I, XT10I, HClI, DELTAI, and A2000I.
Part #
This is the internal computer that controls the HCl instrument.
Part #
This assembly heats the Extraction Chamber of the 220v HCl instrument.
Part #
The H4 valve is a replacement Water Supply Valve for the HCl/HClI. For replacement instructions, refer to Service Procedure Water Supply Valve Installation (H4) (HS003).
Part #
The RF Gas Production System uses rechargeable battery packs ( #RF16 / #RF46 ). The RF25 10-Station Battery Charger is used to charge the RF16/RF46 Rechargeable Battery Packs. As the name says, this charger can charge 10 batteries at one time.
Part #
The pneumatically-operated Diaphragm Valve regulates the input of HCl or Acetic Acid. Refer to Service Procedure Diaphragm Valve Replacement (TS016) for installation instructions.
Part #
The Pump Assembly includes the pump head, motor, and bracket. This pump moves fluids by peristaltic action delivering fluids to the six positions.
Part #
The Temperature Probe w/ ground terminal is used in the DELTA/DELTAI and A2000/A2000I Fiber instruments. This probe provides an accurate vessel temperature which is displayed on the Ascon controller.
Part #
The Lid Assembly is used on the DELTA/DELTAI and A2000/A2000I Fiber instruments and seals the top of the digestion vessel.
Part #
This assembly heats the digestion vessel in the 220v A200I instrument.
Part #
The Outer Exhaust Hose Assembly is used in the DELTA/DELTAI and A200/A200I Fiber instruments. It drains waste solutions from the digestion vessel.
Part #
The Bag Suspender Rod w/ Nut Assembly is used when damage to the rod or pitting has occurred. It runs through the middle of the bag suspender and holds the nine trays in place and is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber...
Part #
The Bag Weigh Holder is used to hold a filter bag open for easy insertion of the sample. This part is especially useful during the weighing process.
Part #
The Hinge Block Assembly is found in the A200/A200I Fiber Instruments. The assembly includes a shoulder bolt and is used to secured the lid to the vessel during sample digestion.
Part #
This hose carries waste from the vessel to the outer exhaust hose. Includes hose with clips.
Part #
This assembly heats the digestion vessel in the 120v instrument.