The Moisture Stop Weigh Pouch contains a desiccant packet which absorbs moisture within the zipper bag. It is used when cooling and weighing filter bags to avoid unwanted absorption of moisture in the dried samples which would skew results.
Part #
The Valve Spring is used inside the solenoid supply valves on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments and is inserted inside the Valve Piston w/ Viton® Seal. Note: For XT10/XT10I and XT15/XT15I -...
Part #
The Water Filter Assembly is found in the DELTA/DELTAI and A2000/A2000I Fiber instruments. It is necessary to filter the water before it enters the valves.
Part #
The A08 Motor Assembly 120v, drives the agitation system in the 120v DELTA & A2000.
Part #
Part #: A29 is not available for purchase on the web. For assistance, please contact ANKOM Technology .
Part #
This 15 amp fuse is used on the DELTA, A2000, and A200, Fiber instruments (120v). It helps protect the instrument from a possible power surge.
Part #
The Temperature Probe w/ ground terminal is used in the DELTA/DELTAI and A2000/A2000I Fiber instruments. This probe provides an accurate vessel temperature which is displayed on the Ascon controller.
Part #
The Lid Assembly is used on the DELTA/DELTAI and A2000/A2000I Fiber instruments and seals the top of the digestion vessel.
Part #
The Outer Exhaust Hose Assembly is used in the DELTA/DELTAI and A200/A200I Fiber instruments. It drains waste solutions from the digestion vessel.
Part #
The Bag Suspender Rod w/ Nut Assembly is used when damage to the rod or pitting has occurred. It runs through the middle of the bag suspender and holds the nine trays in place and is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber...
Part #
The Bag Weigh Holder is used to hold a filter bag open for easy insertion of the sample. This part is especially useful during the weighing process.
Part #
This 10 amp fuse is used on the DELTAI and A2000I Fiber instruments (220v) along with RD (120v) and RDI (220v). It helps protect the instrument from a possible power surge.
Part #
The Pump assembly is found in the DELTA/DELTAI Fiber instruments and includes a fill valve and pump to supply the vessel with chemicals and rinse water.
Part #
This relay monitors the heaters in the following ANKOM instruments: XT15I, XT10I, HClI, DELTAI, and A2000I.
Part #
This relay replaces Part #: 6114 and controls power to the Ascon temperature controller, motor, and drain valve on the DELTA/DELTAI and A2000/A2000I Fiber instruments, as well as the HCl/HClI instrument.
Part #
The A10 Motor Assembly 220v drives the agitation system in the 220v DELTAI & A2000I.
Part #
The Bag Weight Machined is used on the top of the bag suspender within the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It is necessary to hold the trays in place, which, in turn, hold the filter bags in suspension, during the digestion...
Part #
These pre-inked pads are used by the TN2 numbering machine.
Part #
This kit and the accompanying process guide provide the parts and the instructions to complete the Preventative Maintenance (PM) process for the DELTA or A2000 Automated Fiber Analyzers. This procedure should be completed annually for an instrument...
Part #
This container can be used for storing solvents when not in use. When the instrument is properly configured, a cubitainer can also be used for automatically dispensing solvents during an assay. The CUBITAINER® is a disposable flexible package. It can...