Part #
The FLEX-SPE-02 is for use in the ANKOM FLEX Analyte Extractor. The column contains silica-based sorbent material and is used in the extraction step of the instrument for a total fat analysis.
Part #
This 5 cm Cellulose Filter is used in additon to other filters to filter fine particulate in the FLEX Analyte Extractor's digestion vessels. One application includes crude fat analysis.
Part #
The SPE-02 Container is used in crude fat analyses on the ANKOM FLEX Analyte Extractor.
Part #
For use in the ANKOM FLEX Analyte Extractor. SPE Column contains silica-based sorbent material; used in the extraction step of the instrument for a vitamin or cholesterol analysis. These items are sold in packages of 40.
Part #
The 9001 column funnel is an adapter funnel used when running a total fat extraction in an ANKOM FLEX Analyte Extractor.
Part #
For use in the ANKOM FLEX Analyte Extractor. One fat filter is used in each digestion vessel for a fat analysis.
Part #
Fiber Filter Bags 25 micron porosity- 200 Count. Order F57 Filter Bags by 200 count package quantity (e.g. 5 = 1,000 filter bags). Volume discounts will be applied when added to the shopping cart. Quantity discounts apply at 1000, 5000, and 10,000...
Part #
For use in the ANKOM FLEX Analyte Extractor. One vitamin filter is used in each digestion vessel for a vitamin or cholesterol analysis.
Part #
The Sorbent Disposal Bags are used to remove any residual solvent left in the sorbent material after a run is complete. The contents of four SPE columns fit into one Sorbent Disposal Bag. For further instructions, follow the FLEX Service Procedure...
Part #
Order F58 Filter Bags by 100 count package quantity (e.g. 10 = 1,000 filter bags). Volume discounts will be applied when added to the shopping cart. Quantity discounts apply at 1000, 5000, and 10,000 quantities. The F58 filter bag is mainly designed...
Part #
Used for globe vent valve. Located inside the cabinet left side panel.
Part #
For use in the ANKOM FLEX Analyte Extractor. High Strength PTFE magnetic stir-bar; used in each assembled digestion vessel for more difficult to mix samples.
Part #
The Process Pump is the fluid delivery pump used to deliver all reagents from the reservoirs to the vessels.
Part #
The Motor with 4-wire cable is a stepper motor which operates the vessels' magnetic stirrers.
Part #
The FLEX24 High Temperature Thermistor Assembly is marked 56 and is used to monitor the temperature within the oven.
Part #
For use in the ANKOM FLEX Analyte Extractor. Precision ground glass vessel with port and cap; used in the digestion step of the analysis. The port allows the addition of internal standards. A FLEX55 combined with a FLEX54 form a complete Digestion...
Part #
For use in the ANKOM FLEX Analyte Extractor. PTFE magnetic cross stir-bar; used in each assembled digestion vessel.
Part #
For use in the ANKOM FLEX Analyte Extractor. Precision ground round bottom flask with a 34-15 taper ground joint; used in the evaporation step of the instrument.
Part #
Located in #FLEX30 Slide Valve and #FLEX32 Vent Valve assemblies Rev A.
Part #
The Thermal Cut-off Assembly is used in the heater for the oven. It consists of a non-resettable thermal fuse that shuts down power to the heater if the temperature exceeds 240°C.
Part #
The Vent Valve Assembly functions to release pressure from the vessels during vessel fill and saponification.
Part #
The Waste Bottle Assembly is used to capture waste from the FLEX instrument and includes the waste collection bottle, cap, and tubing.
Part #
The Flask Clip Assemblies are an adhesive-backed spring clip used to secure the round bottom flasks in position again the recovery door.
Part #
The Helical Coupler is used on the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It couples the agitator shaft with the motor to provide sample agitation within the vessel. For the A200/A200I instruments, refer to Service Procedure...
Part #
This transformer is used to step up or down the voltage needed for a device. Since ANKOM provides a 120v Water Heater, this transformer is needed if you have a 220v power source.
Part #
This resettable breaker is used to protect the instrument against power surges that are out-of-specification.
Part #
The ETS Snap Disc Thermostat is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It interrupts power to the heating element in an over-temperature condition.
Part #
This assembly includes a probe that provides an accurate temperature to the Athena controller.
Part #
This assembly connects the pressure switch to the digestion vessel.
Part #
This water heater, 120v can be used with the DELTA/DELTAI and A2000/A2000I Fiber instruments. It provides the required hot rinse water for DELTA/A2000 operation. If you have a 220v connection, you will need to connect this water heater to a Voltage...
Part #
The Low Pressure Sensor Assembly is used to monitor nitrogen (N2) line pressure in two locations. One marked 43 monitors N2 going to the four round bottom flasks used for solvent evaporation. One marked 45 monitors N2 Low Pressure and is displayed on...
Part #
The High Pressure Sensor Assembly is used to monitor the main nitrogen input line pressure to the instrument.
Part #
The FLEX21 Thermistor Assemblies are used to monitor temperature at eight locations. One is used to monitor the vessels' temperatures and is marked 46. One is used to monitor the reference temperature surrounding the round bottom flasks and is marked...
Part #
The FLEX Maintenance Kit provides the essential items needed to keep your FLEX Analyte Extractor operating smoohtly. The following items are included: 4 - Container Filters ( Part #: 8202 ) 4 - Vessel Top O-Ring ( Part #: 9231 ) 4 - Column top O-Ring...
Part #
Pneumatic Control Solenoid Valve used in TDF and FLEX Instruments. Replacement part for a faulty Solenoid Valve.
Part #
Used with Digestion Vessel Glass ( Part #: FLEX55 ) seal port.
Part #
Small O-ring located in Vessel Bottom Assembly ( Part #: FLEX54 ) on the bottom side.
Part #
Large O-ring located in the Vessel Bottom Assembly ( Part #: FLEX54 ) on the top, inside.
Part #
The Nitrogen Flowmeter is used to regulate nitrogen flow to FLEX instrument.
Part #
This access panel is designed with a viewing window, allowing users to easily monitor their slide valve condition.
Part #
This is a replacement upper tray for the bag suspender which is found in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. Eight of these are used in the bag suspender assembly.
Part #
These lamps light the inside of the heat and agitate switches.
Part #
The replacement Hose Coupler is used on the DELTA/DELTAI, A200/A200I, and A2000/A2000I Fiber instruments. It connects to the drain hose at the side of the instrument. Includes 2 pieces.
Part #
This bolt is used for securing the lid and hinge block assembly to the vessel.