Part #
Fiber Filter Bags 25 micron porosity- 200 Count. Order F57 Filter Bags by 200 count package quantity (e.g. 5 = 1,000 filter bags). Volume discounts will be applied when added to the shopping cart. Quantity discounts apply at 1000, 5000, and 10,000...
Part #
Order F58 Filter Bags by 100 count package quantity (e.g. 10 = 1,000 filter bags). Volume discounts will be applied when added to the shopping cart. Quantity discounts apply at 1000, 5000, and 10,000 quantities. The F58 filter bag is mainly designed...
Part #
The Helical Coupler is used on the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It couples the agitator shaft with the motor to provide sample agitation within the vessel. For the A200/A200I instruments, refer to Service Procedure...
Part #
This transformer is used to step up or down the voltage needed for a device. Since ANKOM provides a 120v Water Heater, this transformer is needed if you have a 220v power source.
Part #
The ETS Snap Disc Thermostat is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It interrupts power to the heating element in an over-temperature condition.
Part #
This water heater, 120v can be used with the DELTA/DELTAI and A2000/A2000I Fiber instruments. It provides the required hot rinse water for DELTA/A2000 operation. If you have a 220v connection, you will need to connect this water heater to a Voltage...
Part #
This is a replacement upper tray for the bag suspender which is found in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. Eight of these are used in the bag suspender assembly.
Part #
The replacement Hose Coupler is used on the DELTA/DELTAI, A200/A200I, and A2000/A2000I Fiber instruments. It connects to the drain hose at the side of the instrument. Includes 2 pieces.
Part #
At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HS Heat Sealer (120v 50/60HZ) is used for sealing ANKOM Filter Bags. The sealer dimensions are: 13.5"L x 4"W x 8"H
Part #
Replacement cover for the 120v and 220v Heat Sealers (Part #: HS , HSi ). This is applied over the heating element and held in place with clamp strips. For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
The Kynar Tip and Washer assembly is used when the Kynar tip has become worn. It is located at the bottom of the bag suspender used in the DELTA/DELTAI, A200/A200I, and A2000/A2000I Fiber instruments. A worn tip can inhibit proper agitation and...
Part #
The Outer Exhaust Hose Assembly is used in the DELTA/DELTAI and A200/A200I Fiber instruments. It drains waste solutions from the digestion vessel.
Part #
The Bag Suspender Rod w/ Nut Assembly is used when damage to the rod or pitting has occurred. It runs through the middle of the bag suspender and holds the nine trays in place and is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber...
Part #
The Bag Weigh Holder is used to hold a filter bag open for easy insertion of the sample. This part is especially useful during the weighing process.
Part #
The Bag Weight Machined is used on the top of the bag suspender within the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It is necessary to hold the trays in place, which, in turn, hold the filter bags in suspension, during the digestion...
Part #
These pre-inked pads are used by the TN2 numbering machine.
Part #
To properly record results, it is best to label ANKOM Filter Bags before running an assay. The F08 Marker is an acetone resistant black marker that can be used to label ANKOM F57, F58, XT4, and In Situ Bags.
Part #
The Bag Suspender w/ Weight is used within the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It is the entire array that holds the filter bags in the vessel and ensures proper circulation of solutions and uniform digestion of the samples.
Part #
The Packing Set is used in the DELTA/DELTAI, A200/A200I, and A2000/A2000I Fiber instruments. Its purpose is to create a seal and keep the solution from leaking from the vessel into the interior cabinet. This includes two lengths of graphite rope...
Part #
The Brass Packing Nut is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber Instruments. When properly tightened, this ensures that the packing materials create a seal and prevent leaks from the vessel into the interior cabinet. For the A200...
Part #
This is a replacement bottom tray for the bag suspender, which is found in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments.
Part #
Replacement Insulator Strip on the 120v and 220v Heat Sealers (Part #:: HS , HSi ). This is adhesive-backed and positioned beneath the heating element. For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
Replacement Silicone Rubber Gasket for upper pressure bar (in handle) of the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
The Open End Wrench 1-1/8" is used to tighten the Brass Packing Nut ( Part #: 640 ) found on the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments.
Part #
The Agitator Apron is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It serves to funnel fluid away from the motor and into the maintenance alert assembly.
Part #
The Agitator with Packing Set is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. This is used to replace a worn or pitted agitator and with the packing set creates a seal to keep solution from leaking from the vessel into the...
Part #
Replacement Heating element for the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HSi Heat Sealer (220v 50/60HZ) is used for sealing ANKOM Filter Bags. Please specify the country where the heat sealer will be used so that...
Part #
The Moisture Stop Weigh Pouch contains a desiccant packet which absorbs moisture within the zipper bag. It is used when cooling and weighing filter bags to avoid unwanted absorption of moisture in the dried samples which would skew results.
Part #
This stamp works well for marking the F57 and F58 Filter Bags. The ink resists the chemicals and the stamp advances the number each time it is pressed down.
Part #
This 15 amp fuse is used on the DELTA, A2000, and A200, Fiber instruments (120v). It helps protect the instrument from a possible power surge.
Part #
This resettable breaker is used to protect the instrument against power surges that are out-of-specification.
Part #
This assembly includes a probe that provides an accurate temperature to the Athena controller.
Part #
This assembly connects the pressure switch to the digestion vessel.
Part #
The valve seat is attached to the end of the valve piston within the solenoid supply valve used on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments.
Part #
This Viton™ O-ring is used within the solenoid supply valves on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments for proper sealing and replaces the valve body seal O-ring around the inside of the valve guide...
Part #
Replacement heating element for the Water Heater, 120v ( Part #: A02 ).
Part #
Replacement heating element for the A30 Water Heater, 220v (now disconnected).
Part #
The Water Regulator Assembly is found in the DELTA/DELTAI Fiber instruments and helps maintain the appropriate water pressure for rinses and manifold flushing.
Part #
This 90° Brass Elbow is found in the DELTA/DELTAI and A2000/A2000I Fiber instruments and connects the drain valve to the exhaust hose.
Part #
These lamps light the inside of the heat and agitate switches.
Part #
This bolt is used for securing the lid and hinge block assembly to the vessel.
Part #
This part protects the 120v A200 instrument against power surges that are out-of-specification.