Part #
These pre-inked pads are used by the TN2 numbering machine.
Part #
Automated Crude & Detergent Fiber Analysis The ANKOM DELTA Fiber Analyzer automates fiber determinations at the highest level. Capable of Acid Detergent, Neutral Detergent, and Crude Fiber analysis (AOCS Ba 6a-05), the ANKOM DELTA includes an...
Part #
At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HS Heat Sealer (120v 50/60HZ) is used for sealing ANKOM Filter Bags. The sealer dimensions are: 13.5"L x 4"W x 8"H
Part #
Replacement cover for the 120v and 220v Heat Sealers (Part #: HS , HSi ). This is applied over the heating element and held in place with clamp strips. For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
Among other uses, acetone is used as the last rinse in a Dietary Fiber analysis. The FACE product is packaged in a 1 liter bottle. *Special handling is required for International Shipment
Part #
ANKOM FND20 provides laboratories with a quick, convenient and economical way to assure consistent, high quality Neutral Detergent Fiber determination results. *Special handling required for International Shipment
Part #
Reliable In-Vitro Incubation The DAISY II Incubator has a demonstrated history of rigorous testing over a broad range of sample types. Labs around the world have achieved results in In Vitro True Digestibility, Apparent Digestibility, Rate studies...
Part #
To properly record results, it is best to label ANKOM Filter Bags before running an assay. The F08 Marker is an acetone resistant black marker that can be used to label ANKOM F57, F58, XT4, and In Situ Bags.
Part #
Replacement Insulator Strip on the 120v and 220v Heat Sealers (Part #:: HS , HSi ). This is adhesive-backed and positioned beneath the heating element. For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
Replacement Silicone Rubber Gasket for upper pressure bar (in handle) of the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
Combine all FND20C with the accompanying triethylene glycol and add 20L of Distilled Water to make the Neutral Detergent Solution. If you remove only a portion of the dry chemicals to make less than 20L of solution, it is impossible to know if the...
Part #
Replacement Heating element for the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HSi Heat Sealer (220v 50/60HZ) is used for sealing ANKOM Filter Bags. Please specify the country where the heat sealer will be used so that...
Part #
This stamp works well for marking the F57 and F58 Filter Bags. The ink resists the chemicals and the stamp advances the number each time it is pressed down.
Part #
ANKOM FCFB20CB and FCFA20CB provide laboratories with a quick, convenient and economical way to assure consistent, high quality Crude Fiber determination results. *Special handling required for International Shipment
Part #
ANKOM FCFA20CB and FCFB20CB provide laboratories with a quick, convenient and economical way to assure consistent, high quality Crude Fiber determination results. *Special handling required for International Shipment Warning: This product can expose...
Part #
Among other uses, sulfuric acid is used in a lignin determination. FSA-72 is 72% sulfuric acid packaged in a 1 liter bottle. *Special handling is required for International Shipment
Part #
F1N is reagent grade 1N Sulfuric Acid. The product comes in 1 Liter Bottles and is sold in quantities of 4. *Special handling is required for International Shipments
Part #
This transformer is used to step up or down the voltage needed for a device. Since ANKOM provides a 120v Water Heater, this transformer is needed if you have a 220v power source.
Part #
Replacement heating element for the Water Heater, 120v ( Part #: A02 ).
Part #
Replacement heating element for the A30 Water Heater, 220v (now disconnected).
Part #
This water heater, 120v can be used with the DELTA/DELTAI and A2000/A2000I Fiber instruments. It provides the required hot rinse water for DELTA/A2000 operation. If you have a 220v connection, you will need to connect this water heater to a Voltage...
Part #
ANKOM FAD20CB provides laboratories with a quick, convenient and economical way to assure consistent, high quality Acid Detergent Fiber determination results. *Special handling required for International Shipment
Part #
ANKOM FCFA20 when diluted provides 20 L of solution for part A of the Crude Fiber method. *Special handling required for International Shipment
Part #
ANKOM FCFB20 when diluted provides 20 L of solution for part B of the Crude Fiber method. *Special handling required for International Shipment
Part #
DE2 contains 1 kg of Diatomaceous Earth, which is often used to improve the filtration process. Click the link below for the DE2 SDS information.
Part #
FAD20 contains four 1 L bottles of liquid concentrate. Each bottle can be diluted with water to make 5 liters of solution. When diluted, the solution is ready for use in the Acid Detergent method. *Special handling required for International Shipment
Part #
Add 20L of1N-H2SO4 Sulfuric Acid to FAD20C Powder to make the Acid Detergent solution used in the Acid Detergent Fiber method. Refer to the ANKOM A2000 Operator's Manual for the correct formulation.
Part #
DE1 contains 125 grams of Diatomaceous Earth, which is often used to improve the filtration process. Click the link below for the DE1 SDS information.