Part #
This enzyme formulation was developed specifically for use in the ANKOM TDF Dietary Fiber Analyzer. With all of the necessary ingredients in this concentrated formula, add the correct amount of water, and the enzyme solution is ready for use in the...
Part #
This enzyme formulation was developed specifically for use in the ANKOM TDF Dietary Fiber Analyzer. With all of the necessary ingredients in this concentrated formula, just add the correct amount of water and the enzyme solution is ready for use in...
Part #
Among other uses, acetone is used as the last rinse in a Dietary Fiber analysis. The FACE product is packaged in a 1 liter bottle. *Special handling is required for International Shipment
Part #
ANKOM FCFB20CB and FCFA20CB provide laboratories with a quick, convenient and economical way to assure consistent, high quality Crude Fiber determination results. *Special handling required for International Shipment
Part #
This enzyme formulation was developed specifically for use in the ANKOM TDF Dietary Fiber Analyzer. With all of the necessary ingredients in this concentrated formula, add the correct amount of water, and the enzyme solution is ready for use in the...
Part #
This enzyme formulation was developed specifically for use in the ANKOM TDF Dietary Fiber Analyzer. With all of the necessary ingredients in this concentrated formula, add the correct amount of water, and the enzyme solution is ready for use in the...
Part #
ANKOM FAA is a starch-hydrolyzing alpha-amylase enzyme with high heat and pH stability derived from a genetically modified strain of Bacillus licheniformis . FAA is used for liquification of starch during Neutral Detergent Fiber analysis.
Part #
The Rapid Integrated Total Dietary Fiber Assay Kit method is validated under collaborative study (AOAC Method 2017.16, ICC Standard No. 185) and suitable for the measurement and analysis of Total Dietary Fiber as per Codex Alimentarius definition...
Part #
For the AOAC 2017.16/2009.01/2011.25 methods, this enzyme is mixed with AMG when used in the ANKOM TDF Dietary Fiber Analyzer. Contents: 12 g; ca. 75,000 U/g . From porcine pancreas. Partially purified. Free flowing powder. Directions for use in TDF...
Part #
This enzyme formulation was developed specifically for use in the ANKOM TDF Dietary Fiber Analyzer. With all of the necessary ingredients in this concentrated formula, add the correct amount of water, and the enzyme solution is ready for use in the...
Part #
This enzyme formulation was developed specifically for use in the ANKOM TDF Dietary Fiber Analyzer. With all of the necessary ingredients in this concentrated formula, add the correct amount of water, and the enzyme solution is ready for use in the...
Part #
ANKOM FCFA20CB and FCFB20CB provide laboratories with a quick, convenient and economical way to assure consistent, high quality Crude Fiber determination results. *Special handling required for International Shipment Warning: This product can expose...
Part #
ANKOM FND20 provides laboratories with a quick, convenient and economical way to assure consistent, high quality Neutral Detergent Fiber determination results. *Special handling required for International Shipment
Part #
Among other uses, sulfuric acid is used in a lignin determination. FSA-72 is 72% sulfuric acid packaged in a 1 liter bottle. *Special handling is required for International Shipment
Part #
F1N is reagent grade 1N Sulfuric Acid. The product comes in 1 Liter Bottles and is sold in quantities of 4. *Special handling is required for International Shipments
Part #
ANKOM FAD20CB provides laboratories with a quick, convenient and economical way to assure consistent, high quality Acid Detergent Fiber determination results. *Special handling required for International Shipment
Part #
ANKOM FCFA20 when diluted provides 20 L of solution for part A of the Crude Fiber method. *Special handling required for International Shipment
Part #
ANKOM FCFB20 when diluted provides 20 L of solution for part B of the Crude Fiber method. *Special handling required for International Shipment
Part #
Combine all FND20C with the accompanying triethylene glycol and add 20L of Distilled Water to make the Neutral Detergent Solution. If you remove only a portion of the dry chemicals to make less than 20L of solution, it is impossible to know if the...
Part #
Triethylene glycol (FNDTG) combined with FND20C and Distilled Water make up Neutral Detergent Solution.
Part #
DE2 contains 1 kg of Diatomaceous Earth, which is often used to improve the filtration process. Click the link below for the DE2 SDS information.
Part #
FAD20 contains four 1 L bottles of liquid concentrate. Each bottle can be diluted with water to make 5 liters of solution. When diluted, the solution is ready for use in the Acid Detergent method. *Special handling required for International Shipment
Part #
Add 20L of1N-H2SO4 Sulfuric Acid to FAD20C Powder to make the Acid Detergent solution used in the Acid Detergent Fiber method. Refer to the ANKOM A2000 Operator's Manual for the correct formulation.
Part #
DE1 contains 125 grams of Diatomaceous Earth, which is often used to improve the filtration process. Click the link below for the DE1 SDS information.
Part #
RF1X Gas Production Modules can be added to an ANKOM RF Gas Production System (Base Kit). A total of 50 modules can be connected to a GEN 3 RFS system. Please specify a bottle type. NOTE: Standard RF1X modules come with 250ml bottles. For different...
Part #
This larger 4 liter chemical container is used for supplying distilled water to the instrument. The larger size accommodates 8 runs on the instrument before refilling is necessary.
Part #
This holder is used to position the Distilled Water, Buffer, and 78% EtOH containers in the appropriate location next to the instrument.
Part #
This 10 amp fuse is used on the DELTAI and A2000I Fiber instruments (220v) along with RD (120v) and RDI (220v). It helps protect the instrument from a possible power surge.
Part #
The ANKOM RF Maintenance Kit provides the essential tools needed to keep your RF Gas Production System operating smoothly. The following items and instructions for each are included: - (1) RF70: Positive Control Capsule Set (set includes 5 BLUE...
Part #
The Pump assembly is found in the DELTA/DELTAI Fiber instruments and includes a fill valve and pump to supply the vessel with chemicals and rinse water.
Part #
This is the High Pressure Regulator for the TDF instrument.
Part #
For use in the ANKOM FLEX Analyte Extractor. Precision ground glass vessel with port and cap; used in the digestion step of the analysis. The port allows the addition of internal standards. A FLEX55 combined with a FLEX54 form a complete Digestion...
Part #
For use in the ANKOM FLEX Analyte Extractor. PTFE magnetic cross stir-bar; used in each assembled digestion vessel.
Part #
For use in the ANKOM FLEX Analyte Extractor. Precision ground round bottom flask with a 34-15 taper ground joint; used in the evaporation step of the instrument.
Part #
Power Supply A is a 10 amp transformer that supplies 24v DC power to the pump motor controller (PMC) and analog multiplexer boards MUX-T ( Part #: TDF111 ) and MUX-P ( Part #: TDF112 ). This supply is used for both 110v and 220v instruments.
Part #
These bulbs are used for heating the 120-130v DAISY instrument.
Part #
This relay monitors the heaters in the following ANKOM instruments: XT15I, XT10I, HClI, DELTAI, and A2000I.
Part #
This is the internal computer that controls the HCl instrument.
Part #
This assembly heats the Extraction Chamber of the 220v HCl instrument.
Part #
The H4 valve is a replacement Water Supply Valve for the HCl/HClI. For replacement instructions, refer to Service Procedure Water Supply Valve Installation (H4) (HS003).
Part #
The RF Gas Production System uses rechargeable battery packs ( #RF16 / #RF46 ). The RF25 10-Station Battery Charger is used to charge the RF16/RF46 Rechargeable Battery Packs. As the name says, this charger can charge 10 batteries at one time.
Part #
The pneumatically-operated Diaphragm Valve regulates the input of HCl or Acetic Acid. Refer to Service Procedure Diaphragm Valve Replacement (TS016) for installation instructions.
Part #
The Pump Assembly includes the pump head, motor, and bracket. This pump moves fluids by peristaltic action delivering fluids to the six positions.
Part #
The Temperature Probe w/ ground terminal is used in the DELTA/DELTAI and A2000/A2000I Fiber instruments. This probe provides an accurate vessel temperature which is displayed on the Ascon controller.
Part #
The Lid Assembly is used on the DELTA/DELTAI and A2000/A2000I Fiber instruments and seals the top of the digestion vessel.