Part #
The Stainless Steel Latch secures the RD1 or RD2 Filter to the ANKOM Rapid Dryer (RD/RDI). One is used on either side of the Rapid Dryer.
Part #
This part holds the filter bags within the Cup Insert of your XT10/XT10I and XT15/XT15I.
Part #
The RF22.5 Vent Valve Adapter is used to attach the 7043 Syringe to the vent valve tube to aid in cleaning the vent valve on a Gas Production Module (Part #: RF1). For cleaning instructions, see RF Service Procedure Vent Valve Cleaning (RFS006).
Part #
This 1.8L Wide Mouth Bottle assembly attaches directly to an RF1 electrical assembly just like all of the smaller bottles. This RF1 configuration provides the largest bottle by volume and by opening available with the RF Gas Production System. If you...
Part #
This battery kit includes the following: - 1-Dual Lead RF Rechargeable Battery Pack ( Part #: RF46 ) - 1-5 ft Battery Extension Cable ( Part #: RF44 ) - 1-Red Cap with a notch for the extension cable Longer-length cables are available upon request.
Part #
This kit is no longer available. However, the components of the X87 kit can be ordered individually as parts 969.5 and 5806. This O-Ring Kit includes an Extraction Vessel seal ( Part #: 969.5 ) and a Cup Insert Top seal ( Part #: 5806 ). Use this kit...
Part #
This filter is used in the water supply line of the XT10/XT10I and XT15/XT15I.
Part #
The Moisture Stop Weigh Pouch contains a desiccant packet which absorbs moisture within the zipper bag. It is used when cooling and weighing filter bags to avoid unwanted absorption of moisture in the dried samples which would skew results.
Part #
The Valve Spring is used inside the solenoid supply valves on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments and is inserted inside the Valve Piston w/ Viton® Seal. Note: For XT10/XT10I and XT15/XT15I -...
Part #
The pneumatically operated Enzyme Pinch Valve-N.O. regulates the input of enzymes. Refer to Service Procedure Pinch Valve Replacement (Enzymes) (TS009) for installation instructions.
Part #
Replacement exhaust valve for A200/A200I Fiber Analyzer. For replacement instructions, refer to Service Procedure Exhaust Valve Replacement (F2.3) (FS009).
Part #
Replacement locking Safety Valve Assembly for XT10/XT10I and XT15/XT15I. Refer to Service Procedure Valve Replacement (Safety) (XTS004) for installation instructions.
Part #
This module is part of the level-sensing system in the XT15/XT15I. NOTE: Instruments purchased prior to 2012 may have a digital module. Contact ANKOM Technology if you need assistance to determine which module to order.
Part #
The Drain Tray collects waste fluids and funnels them through the Drain Tray Tube to a drain or a collection container provided by the user.
Part #
This 1.8L Wide Mouth Bottle is used in the RF42 assembly and is the largest bottle by volume and by opening available with the RF Gas Production System. If you have a large sample to analyze such as dough, this bottle might work best for your needs...
Part #
The TDF Thermistor Assembly is used to monitor and regulate the power input to the In-line heater to maintain a steady temperature. This is important when pre-heating fluids during rinses and 95% alcohol delivery.
Part #
The TDF99 kit is used to replace pump tubing in the ANKOM TDF instrument. The TDF99 Long-life pump tubes can only be used on instruments outfitted with pumps labeled: "HIGH TORQUE PERISTALTIC PUMP."
Part #
This is the support panel for delivery tubing that directs fluids to the six IDF or SDF positions and out to waste.
Part #
This wrist strap minimizes the static electricity discharge that can negatively affect the programming on the electronics chip within your RF1 module. You should use this strap whenever you are servicing RF1 electronics, including whenever you...
Part #
The pneumatically operated Pinch Valve-IDF, SDF regulates the flow of fluids to the IDF and SDF positions. Refer to Service Procedure Pinch Valve Replacement (Output) (TS008) for installation instructions.
Part #
This is an enzyme container used for supplying Amyloglucosidase (AMG) to the instrument.
Part #
This is a chemical container used for supplying Buffer to the instrument.
Part #
This is a chemical container used for supplying Deionized Water to the instrument.
Part #
The last step in the Dietary Fiber extraction process is to rinse the samples with acetone. That process is not done on the ANKOM TDF instrument. The TDF51 Bag Rinse Stand is used to hold the Filter Bags during an Acetone Rinse.
Part #
This container is used with the AOAC 2009.01/2011.25 methods.
Part #
The RF16 Rechargeable Battery Packs are used to provide power to the RF1 & RF5 Gas Production Module electronics. Use an RF25 10 Station Charger to recharge your batteries.
Part #
The RF22 Vent Valve Cleaning Kit is used to clean the vent valve on a Gas Production Module (RF1). For cleaning instructions, see RF Service Procedure Vent Valve Cleaning (RFS006).
Part #
ANKOM provides many different bottles that can be connected to an RF1 Gas Production Module within the RF Gas Production System. The 7120 bottle provides the following features: - up to 100ml of space to hold analysis material - a protective coating...
Part #
ANKOM provides many different bottles that can be connected to an RF1 Gas Production Module within the RF Gas Production System. The 7128 bottle provides the following features: - up to 500ml of space to hold analysis material - an Amber tint to...
Part #
ANKOM provides many different bottles that can be connected to an RF1 Gas Production Module within the RF Gas Production System. The 7131 bottle provides the following features: - up to 500ml of space to hold analysis material - a protective coating...
Part #
ANKOM provides many different bottles that can be connected to an RF1 Gas Production Module within the RF Gas Production System. The 7154 bottle provides the following features: - up to 250ml of space to hold analysis material - an Amber tint to...
Part #
Amylase is used for liquification of starch during Neutral Detergent Fiber analysis. This A03 amylase container connects to the A2000 instrument and is used for dispensing amylase into the A2000 during the rinse cycle.
Part #
The Water Filter Assembly is found in the DELTA/DELTAI and A2000/A2000I Fiber instruments. It is necessary to filter the water before it enters the valves.
Part #
The A08 Motor Assembly 120v, drives the agitation system in the 120v DELTA & A2000.
Part #
This replacement package contains the following parts: Amylase Container Assembly ( Part #: A03 ) Water Filter Assembly ( Part #: A07 ) Temperature Probe Assembly ( Part #: A17 ) Bag Suspender w/ weight ( Part #: F11 ) Agitator w/ Packing Set ( Part...
Part #
The Waste Bottle Assembly is used to capture waste from the FLEX instrument and includes the waste collection bottle, cap, and tubing.
Part #
The Flask Clip Assemblies are an adhesive-backed spring clip used to secure the round bottom flasks in position again the recovery door.
Part #
This adapter lid with GL45 threads allows RF Modules to fit 1.8L wide mouth jar ( Part #: 7181 ).
Part #
This tube replacement set is used as part of preventative maintenance and includes precut, bagged, and labeled lengths of silicone tubing (1/4”OD x 1/8”ID) used in the supply of reagents in the ANKOM TDF Dietary Fiber Analyzer.
Part #
Part #: A29 is not available for purchase on the web. For assistance, please contact ANKOM Technology .
Part #
This larger 4 liter chemical container is used for supplying EtOH78 to the instrument. The larger size accommodates 8 runs on the instrument before refilling is necessary.
Part #
This larger 10 liter chemical container is used for supplying EtOH95 to the instrument. The larger size accommodates 4 runs on the instrument before refilling is necessary.
Part #
This part protects the 120v instrument against power surges that are out-of-specification.
Part #
Power Supply B is a transformer that supplies 25v DC power to the solenoid valves and paddle heaters. This comes with an in-line fuse kit for overload protection and is used for both 110v and 220v instruments.
Part #
This 15 amp fuse is used on the DELTA, A2000, and A200, Fiber instruments (120v). It helps protect the instrument from a possible power surge.