Part #
This 120/220 volt supply provides the correct power to the instrument electronics.
Part #
The Process Pump is the fluid delivery pump used to deliver all reagents from the reservoirs to the vessels.
Part #
The Motor with 4-wire cable is a stepper motor which operates the vessels' magnetic stirrers.
Part #
The FLEX24 High Temperature Thermistor Assembly is marked 56 and is used to monitor the temperature within the oven.
Part #
Used to hold F57 and F58 Fiber bags for drying in ANKOM RD Dryer. The assembly holds 24 bags. This Bag Drying Rack CANNOT be used in the ANKOM HCl System.
Part #
The TDF129 kit provides all the tubing and parts necessary to perform the annual maintenance for a TDF instrument. This includes all the supply tubing, delivery tubing, enzyme tubing, and all related tubing plus several parts that can fatigue over...
Part #
The Amylase Dispenser connects to the DELTA/DELTAI instrument and is used as a reservoir to dispense amylase into the vessel for digestion of starch during a Neutral Detergent fiber analysis.
Part #
This drive roller connects the motor to the drive pulleys.
Part #
This is a 100 hr timer assembly for monitoring incubation times of samples in the ANKOM Daisy II Incubator (D200/D200I).
Part #
The Kynar Tip and Washer assembly is used when the Kynar tip has become worn. It is located at the bottom of the bag suspender used in the DELTA/DELTAI, A200/A200I, and A2000/A2000I Fiber instruments. A worn tip can inhibit proper agitation and...
Part #
This part protects the 120v A200 instrument against power surges that are out-of-specification.
Part #
To protect the interior of the instrument, this collection chamber catches fluid in the event of an internal leak.
Part #
This assembly shows if the packing has started to leak.
Part #
The RF41 Synthetic Grease w/PTFE is a non-toxic lubricant used to assist in creating a seal between the RF34 Viton® Gasket and the module/bottle, and between the PTFE coated septa and the septa port on the bottle. For application instructions...
Part #
Along with a 3 ft Extension Cable ( Part #: RF44 ), the Dual Lead Rechargeable Battery Pack ( Part #: RF46 ) provides the capability to charge your RF1 module's battery during an experiment by keeping it connected to the Battery Charger ( Part #...
Part #
This is the internal computer that controls the XT15/XT15I Fat Extractor.
Part #
The LCD Screen Assembly is used in the XT10 and XT15 Fat Extractors, the HCl Hydrolysis System, and the DELTA & A2000 Fiber Instruments. Mounted on the front of the instrument, this LCD screen displays temperature, time, and other functions during an...
Part #
Before ordering an XT10/XT10I Extractor Vessel, contact our Technical Services Department to confirm your instrument configuration.
Part #
This part is used to filter solvent vapors and should be replaced every 3 months or after 100 instrument operations. This part is only used in the XT15/XT15I instruments.
Part #
Before ordering an XT15/XT15I Extractor Vessel, contact our Technical Services Department to confirm your instrument configuration.
Part #
The nitrogen check valve prevents fluid back-up from the 12 IDF/SDF delivery lines into the pneumatic lines.
Part #
This is a chemical container used for supplying 95% EtOH to the instrument.
Part #
Before the final weighing step in a Dietary Fiber analysis, the bags must be dried. The TDF50 stainless steel Bag Drying Rack has twelve positions for holding a full set of IDF/SDF bags when drying them in an oven.
Part #
This container is used with the AOAC 2009.01/2011.25 methods.
Part #
This clamp bar is used in the SDF part of the instrument to close the Filter Bag just above the filter.
Part #
This is the controller with display used in the 120v RD Dryer.
Part #
The RF45 and RF45X Programmed RF Chips w/antenna facilitate communication between the Gas Production Modules, the Module Zero, and the Gas Production Base Coordinator.
Part #
The RF2X Base Coordinator facilitates communication between the Gas Production Modules ( RF1X / RF5X ) and the GPM Software installed on a PC. One RF2X Base Coordinator services an RFS base kit of up to 50 modules. To purchase, please contact ANKOM...
Part #
Rinse water enters the digestion vessel through this open/close valve. Refer to Service Procedure Water and Vent Valve Service (AS016) for further information.
Part #
This corrosion resistant fitting connects to the pressure sensor.
Part #
The A32 Fiber Optic Cable and Glass Tip DELTA/A2000 is part of the analog level sensing system in the DELTA and A2000. It is used in conjunction with the ( Part #: A29 ) Level Sensor Analog to detect and regulate the fill level within the vessel...
Part #
The Pressure Sensor Cable connects the Pressure Sensor to the circuit board. This is for A2000/A2000I
Part #
The Pressure Sensor Assembly includes the A41 cable and monitors pressure within the vessel.
Part #
Replacement programmed controller for the D200/D200I Daisy II Incubator. For installation instructions, refer to DAISY Service Procedure Controller Installation (DS002).
Part #
This switch turns the agitation to the digestion vessel on and off.
Part #
The Agitator with Packing Set is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. This is used to replace a worn or pitted agitator and with the packing set creates a seal to keep solution from leaking from the vessel into the...
Part #
The Lid & Hinge Block Assembly is found in the A200/A200I Fiber Instruments. Together, these seal the vessel during sample digestion. The assembly includes both the lid and the hinge block that secures the lid closed, as well as two replacement...
Part #
This assembly includes the O-ring used to seal the digestion vessel and the glue to secure the O-ring.
Part #
This motor agitates the bag suspender at the proper RPM in the 220v instrument.
Part #
The DELTA06 Heating Band Assembly is used in the DELTAI and A2000I Fiber Instruments. It serves to heat the digestion vessel during operation and replaces a failed heating band.
Part #
The Vent Valve Assembly, DELTA is used to release pressure from the top of the vessel and allow for unhindered draining through the drain valve. The vent valve also connects to the vessel pressure sensor.
Part #
The TDF Torsion Bar is used in the ANKOM TDF Dietary Fiber Analyzer to provide torsion adequate to support the front safety cover of the instument.
Part #
This vent valve is used in the jar lid ( Part #: D2.5 ) for releasing pressure from the jars during digestion.