Part #
These pre-inked pads are used by the TN2 numbering machine.
Part #
Among other uses, acetone is used as the last rinse in a Dietary Fiber analysis. The FACE product is packaged in a 1 liter bottle. *Special handling is required for International Shipment
Part #
ANKOM FCFB20CB and FCFA20CB provide laboratories with a quick, convenient and economical way to assure consistent, high quality Crude Fiber determination results. *Special handling required for International Shipment
Part #
At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HS Heat Sealer (120v 50/60HZ) is used for sealing ANKOM Filter Bags. The sealer dimensions are: 13.5"L x 4"W x 8"H
Part #
Replacement cover for the 120v and 220v Heat Sealers (Part #: HS , HSi ). This is applied over the heating element and held in place with clamp strips. For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
To properly record results, it is best to label ANKOM Filter Bags before running an assay. The F08 Marker is an acetone resistant black marker that can be used to label ANKOM F57, F58, XT4, and In Situ Bags.
Part #
Replacement Insulator Strip on the 120v and 220v Heat Sealers (Part #:: HS , HSi ). This is adhesive-backed and positioned beneath the heating element. For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
Replacement Silicone Rubber Gasket for upper pressure bar (in handle) of the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
This transformer is used to step up or down the voltage needed for a device. Since ANKOM provides a 120v Water Heater, this transformer is needed if you have a 220v power source.
Part #
Replacement heating element for the Water Heater, 120v ( Part #: A02 ).
Part #
Replacement heating element for the A30 Water Heater, 220v (now disconnected).
Part #
This water heater, 120v can be used with the DELTA/DELTAI and A2000/A2000I Fiber instruments. It provides the required hot rinse water for DELTA/A2000 operation. If you have a 220v connection, you will need to connect this water heater to a Voltage...
Part #
ANKOM FAD20CB provides laboratories with a quick, convenient and economical way to assure consistent, high quality Acid Detergent Fiber determination results. *Special handling required for International Shipment
Part #
Combine all FND20C with the accompanying triethylene glycol and add 20L of Distilled Water to make the Neutral Detergent Solution. If you remove only a portion of the dry chemicals to make less than 20L of solution, it is impossible to know if the...
Part #
ANKOM FCFA20 when diluted provides 20 L of solution for part A of the Crude Fiber method. *Special handling required for International Shipment
Part #
ANKOM FCFB20 when diluted provides 20 L of solution for part B of the Crude Fiber method. *Special handling required for International Shipment
Part #
ANKOM FCFA20CB and FCFB20CB provide laboratories with a quick, convenient and economical way to assure consistent, high quality Crude Fiber determination results. *Special handling required for International Shipment Warning: This product can expose...
Part #
ANKOM FND20 provides laboratories with a quick, convenient and economical way to assure consistent, high quality Neutral Detergent Fiber determination results. *Special handling required for International Shipment
Part #
Among other uses, sulfuric acid is used in a lignin determination. FSA-72 is 72% sulfuric acid packaged in a 1 liter bottle. *Special handling is required for International Shipment
Part #
F1N is reagent grade 1N Sulfuric Acid. The product comes in 1 Liter Bottles and is sold in quantities of 4. *Special handling is required for International Shipments
Part #
Replacement Heating element for the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HSi Heat Sealer (220v 50/60HZ) is used for sealing ANKOM Filter Bags. Please specify the country where the heat sealer will be used so that...
Part #
This stamp works well for marking the F57 and F58 Filter Bags. The ink resists the chemicals and the stamp advances the number each time it is pressed down.
Part #
DE2 contains 1 kg of Diatomaceous Earth, which is often used to improve the filtration process. Click the link below for the DE2 SDS information.
Part #
Add 20L of1N-H2SO4 Sulfuric Acid to FAD20C Powder to make the Acid Detergent solution used in the Acid Detergent Fiber method. Refer to the ANKOM A2000 Operator's Manual for the correct formulation.
Part #
DE1 contains 125 grams of Diatomaceous Earth, which is often used to improve the filtration process. Click the link below for the DE1 SDS information.
Part #
FAD20 contains four 1 L bottles of liquid concentrate. Each bottle can be diluted with water to make 5 liters of solution. When diluted, the solution is ready for use in the Acid Detergent method. *Special handling required for International Shipment
Part #
The Helical Coupler is used on the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It couples the agitator shaft with the motor to provide sample agitation within the vessel. For the A200/A200I instruments, refer to Service Procedure...
Part #
The valve seat is attached to the end of the valve piston within the solenoid supply valve used on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments.
Part #
This Viton™ O-ring is used within the solenoid supply valves on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments for proper sealing and replaces the valve body seal O-ring around the inside of the valve guide...
Part #
The Water Regulator Assembly is found in the DELTA/DELTAI Fiber instruments and helps maintain the appropriate water pressure for rinses and manifold flushing.
Part #
The ETS Snap Disc Thermostat is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It interrupts power to the heating element in an over-temperature condition.
Part #
This 90° Brass Elbow is found in the DELTA/DELTAI and A2000/A2000I Fiber instruments and connects the drain valve to the exhaust hose.
Part #
This is a replacement upper tray for the bag suspender which is found in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. Eight of these are used in the bag suspender assembly.
Part #
The Valve Piston w/Viton® Seat is used inside the solenoid supply valves on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments and to replace a damaged, worn, or corroded component. DELTA: found in the Vent...
Part #
The RFI Filter 120v/220v is a power receptacle used on the DELTA/DELTAI, A200I, and A2000/A2000I. It is not used on the A200. It is located on the side of the instrument and connects the instrument to a power source through a removable power cord.
Part #
The replacement Hose Coupler is used on the DELTA/DELTAI, A200/A200I, and A2000/A2000I Fiber instruments. It connects to the drain hose at the side of the instrument. Includes 2 pieces.
Part #
The Glass Tip with O-ring is a part of the analog level sensing system in the DELTA/DELTAI, A2000/A2000I Fiber instruments. Found in the Fiber Optic Cable & Glass Tip assembly ( Part #: A32 ), it is used to detect and regulate the fill level within...
Part #
The Copper Water Supply is used to connect the DELTA/DELTAI and A2000/A2000I instruments to the user's water source.
Part #
Used to hold F57 and F58 Fiber bags for drying in ANKOM RD Dryer. The assembly holds 24 bags. This Bag Drying Rack CANNOT be used in the ANKOM HCl System.
Part #
The Amylase Dispenser connects to the DELTA/DELTAI instrument and is used as a reservoir to dispense amylase into the vessel for digestion of starch during a Neutral Detergent fiber analysis.
Part #
The Kynar Tip and Washer assembly is used when the Kynar tip has become worn. It is located at the bottom of the bag suspender used in the DELTA/DELTAI, A200/A200I, and A2000/A2000I Fiber instruments. A worn tip can inhibit proper agitation and...
Part #
The LCD Screen Assembly is used in the XT10 and XT15 Fat Extractors, the HCl Hydrolysis System, and the DELTA & A2000 Fiber Instruments. Mounted on the front of the instrument, this LCD screen displays temperature, time, and other functions during an...
Part #
The Bag Suspender w/ Weight is used within the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It is the entire array that holds the filter bags in the vessel and ensures proper circulation of solutions and uniform digestion of the samples.
Part #
The Packing Set is used in the DELTA/DELTAI, A200/A200I, and A2000/A2000I Fiber instruments. Its purpose is to create a seal and keep the solution from leaking from the vessel into the interior cabinet. This includes two lengths of graphite rope...
Part #
The DELTA01 Maintenance Alert Assembly is used in the DELTA and A2000 instruments. It includes the Drip Tray w/plugged drain hole ( Part #: 692 ), Agitator Apron ( Part #: 638.7 ), and brass washer and functions as a collector for a fluid leak...